The relay chatters when I trigger the door strike

It is not a good idea to use a switching - type power supply to power a door strike or maglock.

Switch mode power supplies like to run on continuous steady drain non-inductive loads. If they go from very low or zero load to a heavy inductive load they sense this as an over current (short circuit) condition and shut down. This may cause the relay to "chatter.”

If you must run a switching power supply with a door-strike or maglock, you will need to install an anti-kickback diode (1N4007) across the DC door strike solenoid, or across the maglock terminals, with the cathode (banded end) connected to the +12 volt side of the supply.

5 (1)
Article Rating (1 Votes)
Rate this article
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Will Allstar work with MVP?
Viewed 2721 times since Mon, Mar 29, 2010
How do I make my clicker brand transmitter work with my Linear garage door operator?
Viewed 4529 times since Mon, Mar 29, 2010
How do I increase the range on my radio receiver?
Viewed 12376 times since Thu, Jun 23, 2011
How do I program my MVP keypad?
Viewed 5285 times since Wed, Apr 7, 2010
How do I program my MDTK keypad?
Viewed 4845 times since Mon, Mar 29, 2010
What products will Multicode work with?
Viewed 3840 times since Mon, Mar 29, 2010
Find Transmitter Code - AP-4, AP-5
Viewed 4621 times since Wed, Mar 31, 2010
How do I program my Stanley keypad?
Viewed 21826 times since Thu, Apr 1, 2010
Open Collector Output
Viewed 3283 times since Fri, Jul 8, 2011
How do I program my DTKP keypad?
Viewed 3933 times since Mon, Mar 29, 2010