How do I wire a strobe light or siren to my receiver?

All Linear receivers that use "dry contact" outputs do not supply voltage from the relays. This means that the receiver does not supply the voltage for the door strike or magnetic lock. You will need a power supply that supplies the correct voltage and sufficient current to operate the door strike or magnetic lock. You can use a single power supply for both the receiver and the door strike or magnetic lock if both the receiver and the lock use the same voltage and the power supply provides sufficient current to operate both devices.You will switch one leg of the power supply for the door strike or magnetic lock through the relay on the receiver.

The wiring would be connected as follows:

  1. Wire one side of the power supply to the common on the receiver relay.
  2. Wire one side of the strobe light or siren to the N/O (normally open) contact on the receiver relay.
  3. Wire the other side of the strobe light or siren to the other side of the power supply.
NOTE: Make sure that the current draw of the door strike or magnetic lock does not exceed the current rating of the relay in the receiver.
1 (1)
Article Rating (1 Votes)
Rate this article
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
How do I set my extended range transmitter and receiver to work together?
Viewed 3340 times since Mon, Apr 5, 2010
How do I program a transmitter into a SXR-64A?
Viewed 2762 times since Mon, Mar 15, 2010
How do I program a transmitter into a security panel?
Viewed 2555 times since Mon, Mar 29, 2010
Can I program with a telephone?
Viewed 2465 times since Mon, Mar 22, 2010
How do I wire a door strike or magnetic lock to my receiver?
Viewed 8730 times since Wed, Apr 14, 2010
DXSR-1504/1508 - Factory Default
Viewed 3108 times since Mon, Mar 8, 2010
How do I program a transmitter into a DXR-701 and DXR-702?
Viewed 6435 times since Mon, Mar 22, 2010
How do I set the output to latch on my Extended Range Receiver?
Viewed 2442 times since Mon, Apr 5, 2010
Is the DXS-80, CO Detector UL listed?
Viewed 2497 times since Tue, Apr 13, 2010
DXS-73 Smoke Detector - Replacing the battery
Viewed 2919 times since Mon, Jul 30, 2012