Hub Max 3: Modular access control system

  1. Supports Wiegand & IEI Secured Series front end readers. Max3 supports both in and out readers connected directly to the module. Max3 supports any Wiegand format up to 39 bits; Supports sounder and LED control.
  2. Faster and more reliable communications – Import transaction in 1/3 of the time as compared to HubMax II systems. The Max 3 system doors will continue to operate normally during a log import or a system export.
  3. Hub Manager® Professional software operational features: System Dashboard –Lock and unlock system door[s] with a click of the mouse from the software and view the door status or event log through "System Dashboard."
  4. Added panel diagnostics for faster installation and improved troubleshooting of communication and relay status on each module.
  5. 2000 Users per door.
  6. Network up to 64 doors.
  7. Supports IEI system keypads & readers as well as Wiegand readers.
  8. 2000 Transaction storage per door.
  9. First-In Auto Unlock.
  10. Eight Time zones per door.
  11. 16 Single Date Holidays per door.
  12. 16 Block Date Holidays per door.
  13. Error Lockout.
  14. Supports Adjustable Daylight Savings Time.
  15. Programmable with Hub Manager® Professional Software 7.2 or higher.
  16. LAN/WAN Connectivity (requires IEI SEG-1or SEG-M).
  17. Serial connection made with USB to 485 converter.

MiniMax 3: Single door access solution

  1. Supports Wiegand & IEI Secured Series front end readers. Max3 supports both in and out readers connected directly to the module. Max3 supports any Wiegand format up to 39 bits; Supports sounder and LED control.
  2. Faster and more reliable communications – Import transaction in 1/3 of the time as compared to HubMax II systems. The Max 3 system doors will continue to operate normally during a log import or a system export.
  3. Hub Manager® Professional software operational features: System Dashboard –Lock and unlock system door[s] with a click of the mouse from the software and view the door status or event log through "System Dashboard."
  4. Added panel diagnostics for faster installation and improved troubleshooting of communication and relay status on each module.
  5. 2000 Users per door.
  6. Network up to 64 doors.
  7. Supports IEI system keypads & readers as well as Wiegand readers.
  8. 2000 Transaction storage per door.
  9. First-In Auto Unlock.
  10. Eight Time zones per door.
  11. 16 Single Date Holidays per door.
  12. 16 Block Date Holidays per door.
  13. Error Lockout.
  14. Supports Adjustable Daylight Savings Time.
  15. Programmable with Hub Manager® Professional Software 7.2 or higher.
  16. LAN/WAN Connectivity (requires IEI SEG-1or SEG-M).
  17. Serial connection made with USB to 485 converter.

Hub Max II: Modular access control system.

  1. 2000 Users.
  2. Network up to 64 doors.
  3. 1500 Transaction storage per door.
  4. First-In Auto Unlock.
  5. Eight Time zones per door.
  6. 16 Holidays per door.
  7. Programmable with Hub Manager® Professional Software.
  8. LAN/WAN Connectivity (requires IEI SEG-1).
  9. Modem compatible (requires IEI SS-Modem).

Hub MiniMax II: Single door access solution.

  1. 2000 Users.
  2. Network up to 64 doors.
  3. 1500 Transaction storage per door.
  4. First-In Auto Unlock.
  5. Eight Time zones per door.
  6. 16 Holidays per door.
  7. Programmable with Hub Manager® Professional Software.
  8. LAN/WAN Connectivity (requires IEI SEG-1).
  9. Modem compatible (requires IEI SS-Modem).

HC500P – Hub Plus Control Module:

  1. Network up to 8 doors.
  2. 8 timezones.
  3. Manage with Hub Manager® Professional.
  4. 1000 users per controller.
  5. 1500 event storage.

Keypads offering stand alone control:

E style:

  1. Single gang flush mount design.
  2. Backlit hardened keys.
  3. Polycarbonate trim.
  4. Key press feedback via sounder and yellow LED.
  5. Built-in assignable sounder.
  6. Bi-color Red/Green LED indicates relay status.
  7. Indoor/outdoor use.
  8. Keypad Programmable.
  9. Five year warranty.
  10. Functionality mode: 2000 Series.

I Style:

  1. Single gang design.
  2. 212i - 1 SPDT 2 amp relay and three 50mA negative.
  3. voltage outputs.
  4. With 212 mode; Optional 293 relay board converts 3 voltage.
  5. outputs to SPDT relays.
  6. 232i - 1 SPDT 2 amp relay and three 1 amp SPDT relays.
  7. Door Position Monitoring – 232 mode only.
  8. Door ajar, Forced door, Alarm shunt outputs – 232 mode only.
  9. Indoor use only.
  10. Functionality mode: 212, 232.

eM Style:

  1. Single gang flush mount design.
  2. Metal Braille alpha-numeric keys.
  3. Brushed metal trim.
  4. Conformal coating.
  5. Key press feedback via sounder and yellow LED.
  6. Built-in assignable sounder.
  7. Bi-color Red/Green LED indicates relay status.
  8. Indoor/outdoor use.
  9. Keypad programmable.
  10. Five year warranty.
  11. Functionality mode: 2000 Series.

W Style:

  1. Single gang design.
  2. 212 w - 1 SPDT 2 amp relay and three 50mA negative.
  3. voltage outputs.
  4. With 212 mode; Optional 293 relay board converts 3 voltage.
  5. outputs to SPDT relays.
  6. 232 w - 1 SPDT 2 amp relay and three 1 amp SPDT relays.
  7. Door Position Monitoring – 232 mode only.
  8. Door ajar, Forced door, Alarm shunt outputs – 232 mode only.
  9. Indoor/outdoor use.
  10. Functionality mode: 212, 232.

IL Style:

  1. Single gang flush mount design.
  2. Hardened backlit keys.
  3. Heavy chrome plated trim ring.
  4. Key press feedback via sounder and yellow LED.
  5. Red & Green LED indicates relay status.
  6. Indoor use only.
  7. Keypad Programmable.
  8. Functionality mode: 212.

iLW Style:

  1. Single gang flush mount design.
  2. Hardened backlit keys.
  3. Heavy chrome plated trim ring.
  4. Key press feedback via sounder and yellow LED.
  5. Built-in assignable sounder.
  6. Bi-color Red/Green LED indicates relay status.
  7. Indoor/outdoor use.
  8. Keypad Programmable.
  9. Functionality mode: 212, 242.

iLM Style:

  1. Surface mount - fits on door mullion.
  2. 1 - 2 amp SPDT relay (212 model).
  3. 3 - 1 amp SPDT relays in controller (232 model).
  4. Door Position Monitoring (232 model).
  5. Door ajar, Forced door, Alarm shunt outputs (232 model).
  6. Backlit hardened keys.
  7. Sounder.
  8. Available in Aluminum or Bronze.
  9. Door bell relay.
  10. Indoor/outdoor use.
  11. Functionality mode: 212, 232.

FX Style:

  1. Heavy chrome plated trim ring.
  2. Flush mount.
  3. Fits single gang electrical box.
  4. Touch sensitive solid-state flat keys.
  5. Bi-color LED to indicate operation.
  6. Indoor/outdoor.
  7. Internal sounder.
  8. Functionality mode: 232.

iLR Style (Discontinued):

  1. Indoor/outdoor weather resistant, self contained metal housing.
  2. Backlit numeric keypad.
  3. Surface mount vandal resistant design.
  4. One piece housing suitable for wall, post, or gooseneck mounting.
  5. 212 mode - 4 on board programmable timed relays.
  6. 232 mode - 1 SPDT 2 amp relay and 3 - 1 amp SPDT access relays.
  7. Door Position Monitoring – 232 mode.
  8. Door ajar, Forced door, Alarm shunt outputs – 232 mode.
  9. Available in two modes of functionality - 212, 232.

R Style:

  1. Indoor/outdoor weather resistant, self contained metal housing.
  2. Surface mount vandal resistant design.
  3. One piece housing suitable for wall, post, or gooseneck mounting.
  4. Durable metal Braille alpha-numeric keys.
  5. 212 mode - 4 on board programmable timed relays.
  6. 232 mode - 1 SPDT 2 amp relay and 3 - 1 amp SPDT access relays.
  7. Door Position Monitoring – 232 mode.
  8. Door ajar, Forced door, Alarm shunt outputs – 232 mode.
  9. Functionality mode: 212, 232.

iLSE Style (Discontinued):

  1. Indoor/outdoor self contained metal housing.
  2. Backlit numeric keypad.
  3. Surface mount vandal resistant design.
  4. One piece housing suitable for wall, post, or gooseneck mounting.
  5. 212 mode - 4 on board programmable timed relays.
  6. 232 mode - 1 SPDT 2 amp relay and 3 - 1 amp SPDT access relays.
  7. Door Position Monitoring – 232 mode.
  8. Door ajar, Forced door, Alarm shunt outputs – 232 mode.
  9. Available in two modes of functionality - 212, 232.

SE Style:

  1. Indoor/outdoor self contained brushed metal housing.
  2. Surface mount vandal resistant design.
  3. One piece housing suitable for wall, post, or gooseneck mounting.
  4. Durable metal Braille alpha-numeric keys.
  5. 212 mode - 4 on board programmable timed relays.
  6. 232 mode - 1 SPDT 2 amp relay and 3 - 1 amp SPDT access relays.
  7. Door Position Monitoring – 232 mode.
  8. Door ajar, Forced door, Alarm shunt outputs – 232 mode.
  9. Tamper loop functionality mode: 212, 232.

Prox.Pad:

  1. Integrated door control, proximity reader and keypad
  2. 2000 users.
  3. 2000 event audit trail.
  4. Bi-color LED to indicate operation.
  5. HID 26 – 37 bit format card compatibility.
  6. Fits over a single gang electrical box.
  7. Corporate 1000 compatible.
  8. Glass mount option included.
  9. Secured Series & Wiegand compatible.
  10. UL 294 Listed.

Mag Card Reader (Discontinued):

  1. Surface mount - fits on door mullion.
  2. 1 – 5 amp SPDT relay in controller.
  3. 3 - 1 amp SPDT relays in controller.
  4. Door Position Monitoring.
  5. Door ajar, Forced door, Alarm shunt outputs.
  6. Bi-color LED to indicate operation.
  7. Indoor/outdoor use.
  8. 120 users.
  9. Functionality mode – 233.

BioRead 1000 & 1100 (Discontinued):

  1. Fingerprint only – no card required.
  2. No PC software required.
  3. Separate door controller to increase secure installations.
  4. 90 Users/Templates.
  5. Authenticate in less than 2 seconds.
  6. Option for Wiegand output (model 1100).
  7. Functionality mode – 212.

PowerKey AC 110 & 220: Industrial (Discontinued)

  1. Lockout unauthorized/untrained users.
  2. 99 Users.
  3. 110/220 Volts AC.
  4. UL Listed.

LS1:

  1. Non-volatile eeprom memory allows in-shop programming.
  2. One non-handed unit for both indoor and outdoor applications.
  3. Wire Raceway provides clean installation and protects wires inside door.
  4. Programs the same as all IEI products.
  5. Durable alphanumeric Braille keys.
  6. Selective Lockout of grouped of users.
  7. Passage/Toggle codes allow door to remain unlocked.
  8. Service codes allow one-time entry then are deleted.
  9. Automatically.
  10. Error Lockout for successive invalid attempts.
  11. Two Stage Low Battery Alert assures entry.
  12. Propped Door and Forced Door alerts when used with a normally open magnetic switch.
  13. Request to Exit allows door to be unlocked from a distance.

LS2 & LS2P:

  1. 2,000 individual users per lockset.
  2. 2,000 transactions stored per lockset.
  3. Wireless lockset programming and audit trail retrieval with.
  4. PDA running Palm OS version 3.5 or newer.
  5. Managed with Hub Manager® Professional Software version 4 or higher.
  6. Unlimited Access Levels including Time Zones and Holidays.
  7. 20,000 users per system.
  8. Unlimited Sites.
  9. Import user names.
    1. LS-2P:
  10. Reads HID proximity cards and fobs up to 37 bit.
  11. Users can be Code, Card, Code and Card, Code or Card.
5 (1)
Article Rating (1 Votes)
Rate this article
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
My WOR is not communicating with the controller.
Viewed 3205 times since Mon, Mar 22, 2010
How do I find the date code on my product?
Viewed 3193 times since Thu, May 6, 2010
What is the procedure for returning a device under warranty?
Viewed 2913 times since Mon, Mar 22, 2010
My light turns green but the door does not unlock.
Viewed 3389 times since Mon, Mar 15, 2010